Powertek is a leading provider of high-quality, customized rack power distribution units (PDUs), and related power solutions to meet the unique needs of demanding datacenters and computerrooms worldwide, releases the new IEXv.2 PDU. Designed according to the latest global standards and using the latest technology to provide you with the industry’s highest availability and smartest power monitoring distribution.
The new POWERTK PDUs is designed with scalability in mind, accommodating the growing power needs of data centers. They can be configured to support a range of voltages and current ratings up to 200A, making them adaptable to various environments
IEX (C13/C15/C19/21) all in one combo socket makes the PDU the most versatile, coping with any combination of C14 and C20 plugs
Emphasizes innovation, modularity, and adaptability. Engineered to thrive in diverse environments, offering a forward-thinking solution
Allows the linking of 2 PDUs where the Primary unit has the power information from the Link units. Ensures redundant power for the main Controller for both units, even if the Primary unit loses power
USB A and C
USB ports enables simultaneous connectivity to mobile interfaces, rapid PDU configurations, mass firmware updates
Temperature, Humidity, Water leakage,
Vibration, Smoke, Door contacts
Cascade upto 16 sensors
Dual Ethernet 10/100/1000
Enables connectivity to network infrastructure. Physically cascade 32
PDUs under one ethernet port using bridging mode (RSTP), or additionally, save IP addresses using a single IP address with port forwarding
Provides information on power usage, outlet status, and critical alerts. Autoflip display
Temperature, Humidity, Water leakage,
Vibration, Smoke, Door contacts
Cascade upto 16 sensors
Allows the linking of 2 PDUs where the Primary unit has the power information from the Link units. Ensures redundant power for the main Controller for both units, even if the Primary unit loses power
USB A and C
USB ports enables simultaneous connectivity to mobile interfaces, rapid PDU configurations, mass firmware updates
Dual Ethernet 10/100/1000
Enables connectivity to network infrastructure. Physically cascade 32
PDUs under one ethernet port using bridging mode (RSTP), or additionally, save IP addresses using a single IP address with port forwarding
Temperature, Humidity, Water leakage,
Vibration, Smoke, Door contacts
Cascade upto 16 sensors
Easily view the health status of the PDU with our giant multi-color light indicators, these report both warning and critical alarms.
Uses energy efficient bi-stable latching relays. These relays consume up to 70% less energy than alternatives, making outlet switching safer and configured in such a way that the outlet power distribution is always maintained.
Coloured PDUs make it easier to reduce human errors, identify power feeds, lowering the risk of unplanned downtime, Powertek PDUs are available in any RAL-colour.
Coloured PDUs make it easier to reduce human errors, identify power feeds, lowering the risk of unplanned downtime, Powertek PDUs are available in any RAL-colour.
The Powertek IEXv2 PDU excels on quality power metrics reaching the highest level accuracy of the market analyzing all possible sources of troubles that can occur on a high power demand data center
High power density electronics design allows AI-HYPER PDUs to offer the maximum performance x outlet in the market, any device can draw up to 20A x outlet all this secured with an individual 10kA UL489 20A breaker.
Allows you to monitor the total load across each outlet, during an overload event the circuit breaker will trip, using POWERTEK ANALYTICS you can visualize the wave form that could cause the overcurrent, and switch OFF the outlet in case of a suspicious power failure.
AI-Hyper PDUs gives real time 0,5% accuracy monitoring the most critical parameters required for a proper power quality metrics like peak current, phase angle, power factor, apparent energy, reactive power and total harmonic distortion.
Current harmonics increase RMS current, causing power losses, overheating, and equipment damage while disrupting power distribution. Voltage harmonics distortions impact